首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Combined effect of light intensity and temperature on the magnetic resonance linewidth in alkali vapor cell with buffer gas
Institution:1.School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China;2.School of Electronic and Information Engineering, Beihang University, Beijing 100191, China
Abstract:One of the peculiar phenomenons in non-zero magnetic resonance magnetometer is that, with the increase of the temperature, the magnetic resonance linewidth is narrowed at first instead of broadened due to the increasing collision rate. The magnetometer usually operates at the narrowest linewidth temperature to obtain the best sensitivity. Here, we explain this phenomenon quantitatively considering the nonlinear of the optical pumping in the cell and did experiments to verify this explanation. The magnetic resonance linewidth is measured using one amplitude-modulated pump laser and one continuous probe laser. The field is along the direction orthogonal to the plane of pump and probe beams. We change the temperature from 53℃ to 93℃ and the pumping light from 0.1 mW to 2 mW. The experimental results agree well with the theoretical calculations.
Keywords:atomic magnetometer  magnetic resonance  linewidth  temperature  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国物理 B》浏览原始摘要信息
点击此处可从《中国物理 B》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号