Baseline correction combined partial least squares algorithm and its application in on-line Fourier transform infrared quantitative analysis |
| |
Authors: | Peng Jiangtao Peng Silong Xie Qiong Wei Jiping |
| |
Affiliation: | aInstitute of Automation, Chinese Academy of Sciences, Beijing 100190, PR China;bFood Research Institute of Tianshili Group, Tianjin 300410, PR China |
| |
Abstract: | In order to eliminate the lower order polynomial interferences, a new quantitative calibration algorithm “Baseline Correction Combined Partial Least Squares (BCC-PLS)”, which combines baseline correction and conventional PLS, is proposed. By embedding baseline correction constraints into PLS weights selection, the proposed calibration algorithm overcomes the uncertainty in baseline correction and can meet the requirement of on-line attenuated total reflectance Fourier transform infrared (ATR-FTIR) quantitative analysis. The effectiveness of the algorithm is evaluated by the analysis of glucose and marzipan ATR-FTIR spectra. BCC-PLS algorithm shows improved prediction performance over PLS. The root mean square error of cross-validation (RMSECV) on marzipan spectra for the prediction of the moisture is found to be 0.53%, w/w (range 7–19%). The sugar content is predicted with a RMSECV of 2.04%, w/w (range 33–68%). |
| |
Keywords: | Attenuated total reflectance Fourier transform infrared Baseline correction Partial Least Squares Weight selection |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|