Guderley reflection for higher Mach numbers in a standard shock tube
Authors:A Cachucho  B W Skews
Institution:(1) Flow Research Unit, University of the Witwatersrand, PO WITS, 2050, Johannesburg, South Africa
Abstract:An experimental study shows that the Guderley reflection (GR) of shock waves can be produced in a standard shock tube. A new technique was utilised which comprises triple point of a developed weak Mach reflection undergoing a number of reflections off the ceiling and floor of the shock tube before arriving at the test section. Both simple perturbation sources and diverging ramps were used to generate a transverse wave in the tube which then becomes the weak reflected wave of the reflection pattern. Tests were conducted for three ramp angles (10°, 15°, and 20°) and two perturbation sources for a range of Mach numbers (1.10–1.40) and two shock tube expansion chamber lengths (2.0 and 4.0 m). It was found that the length of the Mach stem of the reflection pattern is the overall vertical distance traveled by the triple point. Images with equivalent Mach stem lengths in the order of 2.0 m were produced. All tests showed evidence of the fourth wave of the GR, namely the expansion wave behind the reflected shock wave. A shocklet terminating the expansion wave was also identified in a few cases mainly for incident wave Mach numbers of approximately 1.20.