摘    要:样品采用索氏抽提,抽提液依次经酸性硅胶床、多段混合硅胶柱和凝胶渗透色谱柱(GPC)净化后,用Florisil硅藻土柱分离出样品中的二噁英(PCDD/Fs)和类二噁英多氯联苯(dioxin-like PCBs),采用同位素稀释法和气相色谱/高分辨质谱联用仪(GC/HRMS)测定了其中的17个2,3,7,8-氯取代二噁英类化合物和12个类二噁英多氯联苯。结果表明,用该法分析二噁英和多氯联苯标准溶液,平行4次的分析结果为:RSD(PCDD/Fs)<8.9%,RSD(PCBs)<11.4%;回收率可达60%-105%。PCDD/Fs和PCBs的检出限分别为0.1-0.8 pg/g和0.05-0.6 pg/g。应用本方法成功测定了沉积物、淤泥、土壤和飞灰中的二噁英和类二噁英多氯联苯,并计算出它们的毒性当量。

关 键 词:二噁英  类二噁英多氯联苯  气相色谱/高分辨质谱  Florisil硅藻土柱  环境样品
修稿时间:2006-06-182006-09-29

Determination of 2,3,7,8-Substituted Polychlorinated Dibenzo-p-dioxins-Dibenzofurans and Dioxin-like Polychlorinated biphenyls in Environmental Samples by Gas Chromatography/High Resolution Mass Spectrometry
Ren Man,Peng Ping-An,Zhang Su-Kun,Deng Yun-Yun,Mai Bi-Xian,Sheng Guo-Ying,Fu Jia-Mo.Determination of 2,3,7,8-Substituted Polychlorinated Dibenzo-p-dioxins-Dibenzofurans and Dioxin-like Polychlorinated biphenyls in Environmental Samples by Gas Chromatography/High Resolution Mass Spectrometry[J].Chinese Journal of Analytical Chemistry,2007,35(2):176-180.
Authors:Ren Man  Peng Ping-An  Zhang Su-Kun  Deng Yun-Yun  Mai Bi-Xian  Sheng Guo-Ying  Fu Jia-Mo
Institution:Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640
Abstract:A method was evaluated for the determination of seventeen 2,3,7,8-substitituted polychlorinated dibenzo-p-dioxins and dibenzofurans(PCDD/Fs) and 12 dioxin-like polychlorinated biphenyls(PCBs) in environmental samples with isotope dilution-gas chromatography/high resolution mass spectrometry.Sample extracts were cleaned up successively with acid silica gel slurry,multi-layer silica gel column and gel permeation chromatography column.Florisil column was used to separate PCBs from PCDD/Fs.Precise and recoveries of the entire procedure were evaluated by replicate analysis(n=4) of PCDD/Fs and PCBs standard solutions,with RSD below 8.9% and 11.4% for PCDD/Fs and PCBs,respectively,and with the recoveries in the range of 60%-105%.The detection limits of PCDD/Fs and dioxin-like PCBs were 0.1-0.8 pg/g and 0.05-0.6 pg/g respectively.PCDD/Fs and dioxin-like PCBs were successfully determined in environmental samples such as sediment,slurry,soil and fly ash,and then their toxic equivalent was calculated.