首页 | 本学科首页   官方微博 | 高级检索  
     

人眼的高级像差对视功能的影响
引用本文:王杨,王肇圻,郭欢庆,全薇. 人眼的高级像差对视功能的影响[J]. 光学学报, 2005, 25(11): 519-1525
作者姓名:王杨  王肇圻  郭欢庆  全薇
作者单位:南开大学现代光学研究所,天津,300071;吉林大学通信工程学院,长春,130022
基金项目:国家自然科学基金重点项目(60438030)、教育部南开大学天津大学合作基金项目和天津市科技攻关项目(033183711)资助课题.
摘    要:准确测量和分析人眼的高级像差有助于更好地改善视觉,具有重要的实验和临床意义。测量了实际人眼的波前像差,分析了高级像差对人眼视功能的影响。像差数据由哈特曼-夏克(Hartmann-Shack)波前传感器分别对不同瞳孔的人眼进行测量而获得,视功能的评价方法采用了调制传递函数(MTF)、对比敏感度函数(CSF)、斯特雷尔(Strehl)比率。由人眼的波前像差数据和视网膜空间像调制度(AIM)曲线直接给出了视锐度值与对比敏感度值。矫正了离焦与像散后.被测者的平均视锐度值达到了1.0,对比敏感度在低频(20c/mm)处约为52,高频(80c/mm)处约为1;矫正了前4阶像差后,平均视锐度值可提高到1.2,对比敏感度在低频(20c/mm)处提高到96,高频(80c/mm)处提高到7。实际人眼各不相同,达到理想成像需矫正高级像差的阶数也不同。矫正了前九阶像差后,均可达到理想成像,斯特雷尔比率值大于0.8。

关 键 词:医用光学与生物技术  波前像差  视功能  对比敏感度  斯特雷尔比率  视锐度
文章编号:0253-2239(2005)11-1519-7
收稿时间:2004-12-27
修稿时间:2005-03-17

Impact of Higher-Order Wavefront Aberrations of Human Eyes on Vision Performance
Wang Yang,Wang Zhaoqi,Guo Huanqing,Quan Wei. Impact of Higher-Order Wavefront Aberrations of Human Eyes on Vision Performance[J]. Acta Optica Sinica, 2005, 25(11): 519-1525
Authors:Wang Yang  Wang Zhaoqi  Guo Huanqing  Quan Wei
Affiliation:1. Institute of Modern Optics, Nankai University, Tianjin 300071; 2. College of Communication Engineering, Jilin University, Changchun 130022
Abstract:Accurate measurement of higher-order wavefront aberrations helps to improve retinal image quality and has an important clinical value.Wavefront aberrations of human eyes have been measured and the impact of higher-order aberrations on vision has been evaluated in this article.Hartmann-Shack wavefront sensor is used to measure the aberrations and the eye's vision is evaluated with modulation transfer function MTF,contrast sensitivity function CSF and Strehl ratio.Visual acuity and CSF values were directly given from wavefront aberrations and the retinal aerial image modulation AIM of human eyes.After correcting defocus and astigmatism,the average visual acuity of subjects is 1.0,the CSF value is about 52 for lower frequency 20 c/mm and about 1 for higher frequency 80 c/mm. After removing the 2nd,3rd and 4th Zernike aberrations,the average acuity reached 1.2,the CSF value is about 96 for lower frequency 20 c/mm and about 7 for higher frequency 80 c/mm. Different people has its specific aberrations,so different order of aberrations must be corrected to reach the satisfactory imaging.After correcting the 2nd up to 9th Zernike aberrations,the Strehl ratios of three subjects are all in the ideal state and the average value is greater than 0.8.
Keywords:medical optics and biotechnology   wavefront aberration   vision performance   contrast sensitivity   Strehl ratio   visual acuity
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号