Determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol by temperature-controlled ionic liquid dispersive liquid-phase microextraction combined with high performance liquid chromatography-fluorescence detector
Authors:Zhou Qingxiang  Gao Yuanyuan  Xie Guohong
Institution:a Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huaihe River Water Environment and Pollution Control, Ministry of Education, School of Chemistry and Environmental Sciences, Henan Normal University, Xinxiang 453007, China
b State Laboratory of Petroleum Resource and Prospecting, Key Laboratory of Earth Prospecting and Information Technology, College of Geosciences, China University of Petroleum Beijing, Beijing 102249, China
c College of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China
Abstract:Present study described a simple, sensitive, and viable method for the determination of bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in water samples using temperature-controlled ionic liquid dispersive liquid-phase microextraction coupled to high performance liquid chromatography-fluorescence detector. In this experiment, 1-octyl-3-methylimidazolium hexafluorophosphate (C8MIM]PF6]) was used as the extraction solvent, and bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol were selected as the model analytes. Parameters affecting the extraction efficiency such as the volume of C8MIM]PF6], dissolving temperature, extraction time, sample pH, centrifuging time and salting-out effect have been investigated in detail. Under the optimized conditions, good linear relationship was found in the concentration range of 1.0-100 μg L−1 for BPA, 1.5-150 μg L−1 for 4-NP, and 3-300 μg L−1 for 4-OP, respectively. Limits of detection (LOD, S/N = 3) were in the range of 0.23-0.48 μg L−1. Intra day and inter day precisions (RSDs, n = 6) were in the range of 4.6-5.5% and 8.5-13.3%, respectively. This method has been also successfully applied to analyze the real water samples at two different spiked concentrations and excellent results were obtained.
Keywords:Temperature-controlled ionic liquid dispersive liquid-phase microextraction  Bisphenol A  4-N-nonylphenol  4-Tert-octylphenol  1-Octyl-3-methylimidazolium hexafluorophosphate  High performance liquid chromatography-fluorescence detector