首页 | 本学科首页   官方微博 | 高级检索  
     检索      

电感耦合等离子体光谱法测定新疆奎屯氟砷中毒患者尿中的14种元素含量的研究
引用本文:孙莲,刘海,常军民,刘开泰,杨培君,冯艳波.电感耦合等离子体光谱法测定新疆奎屯氟砷中毒患者尿中的14种元素含量的研究[J].光谱学与光谱分析,2005,25(8):1351-1354.
作者姓名:孙莲  刘海  常军民  刘开泰  杨培君  冯艳波
作者单位:1.新疆医科大学化学教研室,新疆 乌鲁木齐 830054
2.新疆医科大学预防医学系,新疆 乌鲁木齐 830054
3.新疆有色地勘局测试中心,新疆 乌鲁木齐 830000
基金项目:国家自然科学基金资助项目
摘    要:建立一种用电感耦合等离子体光谱法测定氟中毒,氟砷联合中毒患者尿中的K,Na,Ca,Mg,P,Zn,Al,Ba,Co,Cu,Ni,Sr,Cr,Ti 14种元素含量的方法。研究了电感耦合等离子体光谱法的操作条件及各元素的检出限,精密度和线性范围,方法的相对标准偏差为0.24%~2.47%(n=10)。平均回收率为90.4%~100.5%。与健康对照组比较,氟中毒和氟砷联合中毒患者组尿中的K,Na的含量高于健康对照组;氟砷联合中毒患者尿液中的Ba,Co,Cu,Ni,Cr的含量比氟中毒组和对照组的要高,具有统计学意义(P<0.05)。P,Ca,Mg,Zn,Al,Ti,Sr三组间比较无统计学意义(P>0.05)。方法灵敏,简单,重现性好,数据可靠。

关 键 词:电感耦合等离子体光谱  氟中毒  氟砷联合中毒  无机元素  
文章编号:1000-0593(2005)08-1351-04
收稿时间:09 16 2004 12:00AM
修稿时间:01 28 2005 12:00AM

Determination of the Contents of Fourteen Elements in Urine of Xinjiang Kuitun Fluorine Poisoning and Arsenic-Fluoride Poisoning Patients by ICP-AES
SUN Lian,LIU Hai,CHANG Jun-min,LIU Kai-tai,YANG Pei-jun,FENG Yan-bo.Determination of the Contents of Fourteen Elements in Urine of Xinjiang Kuitun Fluorine Poisoning and Arsenic-Fluoride Poisoning Patients by ICP-AES[J].Spectroscopy and Spectral Analysis,2005,25(8):1351-1354.
Authors:SUN Lian  LIU Hai  CHANG Jun-min  LIU Kai-tai  YANG Pei-jun  FENG Yan-bo
Institution:1.Xinjiang Medical University,Chemistry Department, Urumqi 830054, China2.Xinjiang Medical University,Preventing Medicine Department, Urumqi 830054, China3.Geological Prospecting Determing Centre, Urumqi 830000, China
Abstract:A method of determining the contents of K, Na, Ca, Mg, P, Zn, Al, Ba, Co, Cu, Ni, Sr, Cr and Ti, fourteen elements, in urine of Xinjiang Kuitun fluorine poisoning and arsenic-fluoride poisoning patients was developed. The operation conditions of ICP-AES, and the lowest test concentration, precision and linear ranges were studied. The relative standard deviation of the method was 0.24%-2.47%(n=10), the average recoveries were 90.4%-100.5%. The contents of K and Na in urine of fluorine poisoning and arsenic-fluoride poisoning patients were higher than those of healthy contrast group. The contents of Ba, Co, Cu, Ni and Cr in the urine of arsenic-fluoride poisoning patients were higher than those of fluorine poisoning patients and healthy contrast group(P<0.05). The contents of P, Ca, Mg, Zn, Al, Sr and Ti do not have statistic significance(P>0.05). The method was sensitive, simple and accurate. The experiment data was reliable.
Keywords:ICP-AES  Fluorine poisoning and arsenic-fluoride poisoning  Inorganic elements
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏