摘    要:为对地冲击作用下地下结构进行有效防护,提出一种泡沫混凝土材质的新型防护构件。与使用实心泡沫混凝土层的防护机理不同,本文中提出的构件在地冲击作用下,首先发生脆断破坏,然后破碎块体间搭接折断、挤压密实。通过构造设计,截断地冲击荷载,减弱荷载传递,改变被保护结构上的荷载形式。通过场地爆炸实验对比了不同防护措施下(无防护、实心泡沫混凝土层防护及新型构件防护)被保护结构的动力响应。实验结果表明:新型构件防护通过脆断、破碎块体的搭接、挤压密实表现出较实心泡沫混凝土层防护更好的防护效果;新型构件防护由于脆断特性,在较小荷载下即可显著削弱荷载传递,避免了实心泡沫混凝土层防护中负效果的出现;地冲击荷载较强时,构件防护层趋于压实,其防护效果逐渐接近实心泡沫混凝土层。

关 键 词:泡沫混凝土    地冲击    地下结构    脆断破坏    荷载传递
收稿时间:2022-01-27

Experimental study on the protective performance of a new brittle component subjected to ground shock
Institution:1.Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing 100124, China2.State Key Laboratory of Explosion Science and Technology, Beijing Institute of Technology, Beijing 100081, China3.Institute of Engineering Protection, Institute of Defense Engineering, Academy of Military Sciences, Luoyang 471023, Henan, China
Abstract:To effectively protect the underground structures subjected to ground shock, a new protective component made of foam concrete was proposed. Different from the mechanism of the solid foam concrete layer protection, under the action of ground shock, the proposed components firstly exhibited brittlely fracture, and the fractured parts underwent recontact and compaction, in which the ground shock truncation, load transferred reduction and load form modification on the structures were achieved with the response of the designed components. A field experiment was conducted and the comparison of the dynamic response of the structure (with different protection scenarios, i.e. without protection, with a solid foam concrete layer protection and with the proposed component layer protection) suggested that the superior protective performance was achieved with the fracture, recontact, compaction of the new component. Due to the brittle fracture, the load transfer could be significantly reduced under a relatively low ground shock level, with which the negative protection effect using solid foam concrete layer could be avoided. Subjected to a relatively strong ground shock, the proposed component layer tended to compaction, and its protection effect gradually approached that with the solid foam concrete layer.