首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Microfluidic operations using deformable polymer membranes fabricated by single layer soft lithography
Authors:Sundararajan Narayan  Kim Dongshin  Berlin Andrew A
Institution:Precision Biology, CTM/Intel Research, Intel Corp., 2200 Mission College Blvd., Santa Clara, CA 95054, USA. narayan.sundararajan@intel.com
Abstract:We show that it is possible to use single layer soft lithography to create deformable polymer membranes within microfluidic chips for performing a variety of microfluidic operations. Single layer microfluidic chips were designed, fabricated, and characterized to demonstrate pumping, sorting, and mixing. Flow rates as high as 0.39 microl min(-1) were obtained by peristaltic pumping using pneumatically-actuated membrane devices. Sorting was attained via pneumatic actuation of membrane units placed alongside the branch channels. An active mixer was also demonstrated using single-layer deformable membrane units.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏