首页 | 本学科首页   官方微博 | 高级检索  
     


Directivity calculation with experimental verification for a conformal array of underwater acoustic transducers
Authors:HE Zhengyao  MA Yuanliang
Affiliation:Institute of Acoustic Engineering, Northwestern Polytechnical University Xi'an 710072
Abstract:
The radiation directivity of a complicated conformal array of underwater acoustic transducers is presented based on the boundary 'element method. It includes the element directivity of each transducer, the natural beam pattern and the controlled beam pattern of the transducer array. At first, the boundary element model of the conformal array is built up, and then the boundary condition is exerted on the model according to the design and environment in which the transducer array is used, and the radiation directivity of the conformal array is calculated. An experiment has been done to measure the directivity in an anechoic water tank.The calculated and the experimental results are compared and analyzed. They are consistentto each other. It is shown that the boundary element method together with the detailed calculations is successful to simulate and predict the radiation directivity of an underwater acoustic transducer array.
Keywords:acoustic  array  conformal  experimental verification  calculation  boundary element method  successful  simulate  predict  results  measure  water tank  boundary condition  design  environment  used  model  natural  controlled  beam
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号