首页 | 本学科首页   官方微博 | 高级检索  
     

光电倍增管对14 MeV脉冲中子的直照响应
引用本文:陈亮,欧阳晓平,张忠兵,张国光,张建福,张显鹏. 光电倍增管对14 MeV脉冲中子的直照响应[J]. 强激光与粒子束, 2007, 19(2): 335-338
作者姓名:陈亮  欧阳晓平  张忠兵  张国光  张建福  张显鹏
作者单位:西北核技术研究所,西安,710024;西北核技术研究所,西安,710024;西北核技术研究所,西安,710024;西北核技术研究所,西安,710024;西北核技术研究所,西安,710024;西北核技术研究所,西安,710024
基金项目:西北核技术研究所预研项目资助课题
摘    要:
 采用ING-103型DPF脉冲中子源产生的14.1 MeV脉冲中子对EMI两个不同型号的光电倍增管EMI-9815B和EMI-9850B进行了直照实验。针对DPF脉冲中子源产生中子脉冲的同时也会产生X射线脉冲的特点,采取了飞行时间法及吸收衰减法来消除X射线对中子脉冲的干扰。利用中子及X射线速度的差异,将光电倍增管放置在离源较远的测点位置,测得了X射线脉冲和中子脉冲时间上错开的双峰波形。通过在辐射通道内添加5 cm厚的铅吸收体有效地抑制了X射线峰,在离源较近的测量位置测到了干净的脉冲中子波形。根据实测波形,得到的光电倍增管EMI-9815B和EMI-9850B中子直照灵敏度分别为10-13与10-15量级,该结果与理论计算结果在量级上一致。

关 键 词:光电倍增管  直照响应  灵敏度  脉冲中子
文章编号:1001-4322(2007)02-0335-04
收稿时间:2006-07-28
修稿时间:2006-07-28

Response of photomultiplier tube to 14 MeV pulse neutron irradiation
CHEN Liang,OUYANG Xiao-ping,ZHANG Zhong-bing,ZHANG Guo-guang,ZHANG Jian-fu,ZHANG Xian-peng. Response of photomultiplier tube to 14 MeV pulse neutron irradiation[J]. High Power Laser and Particle Beams, 2007, 19(2): 335-338
Authors:CHEN Liang  OUYANG Xiao-ping  ZHANG Zhong-bing  ZHANG Guo-guang  ZHANG Jian-fu  ZHANG Xian-peng
Affiliation:Northwest Institute of Nuclear Technology, P.O.Box 69, Xi’an 710024, China
Abstract:
The response of photomultiplier tube(PMT) to scattered neutron and gamma ray is a severe interfere factor in low sensitivity scintillation neutron detection system.The response waveforms of PMT to 14.1 MeV pulse neutron is measured upon the ING-103 DPF pulse neutron source system,using two different types of PMT(EMI-9815B and EMI-9850B).To ensure the DPF source produce pulse neutron and X-ray simultaneously,it is essential to eliminate the X-ray's interference.Through time of flight(TOF) method,the neutron and X-ray pulse are separated because of their different arriving time at the ulterior detection point.The net neutron pulse is detected by adding a Pb absorber in the beam channel to restrain the X-ray.The experimental sensitivity of the EMI-9815B and EMI-9850B are 10(-13) and 10(-15) magnitude,respectively,is agreed well with the calculational results by MCNP Monte-Carlo program.
Keywords:Photomultiplier tube  Irradiation response  Sensitivity  Pulse neutron