首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Submillimeter Laser Interferometer-Polarimeter for Plasma Diagnostics
Authors:Yu E Kamenev  V K Kiseliov  Ye M Kuleshov  B N Knyaz'kov  V K Kononenko  P K Nesterov and M S Yanovsky
Institution:(1) Institute of Radiophysics and Electronics, National Academy of Sciences of Ukraine, 12, Acad. Proskura Street, Kharkov, 310085, Ukraine
Abstract:The testing results of a homodyne 0.195-mm laser interferometer-polarimeter based on quasioptical components are presented. The interferometer-polarimeter matched to the multichannel interferometer of a Tokamak-15 machine admits of simultaneous measurements of the plasma electron density and poloidal magnetic field in one of the seven vertical-probing channels without any disturbance in the others. The achieved responce threshold of the electron density is 3.4·1011 cm–3, the polarization resolution and the phase difference measurement error are no worse than 0,10 and ±40, respectively.
Keywords: