首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of molecular parameters for 1,3-butadiene and propylene using infrared tunable diode laser absorption spectroscopy
Authors:Harward Charles N  Baren Randall E  Parrish Milton E
Institution:Nottoway Scientific Consulting Corporation, 10379 East Colonial Trail Highway, Nottoway, VA 23930, USA.
Abstract:A technique has been developed for the determination of molecular parameters, including infrared absorption line positions, strengths, and nitrogen-broadened half-widths for 1,3-butadiene (C(4)H(6)) and propylene (C(3)H(6)). The parameters for these two molecules are required for quantitation using Tunable Diode Laser Absorption Spectroscopy (TDLAS). These molecules have populations of highly overlapping infrared absorption lines in their room temperature spectra. The technique reported here provides a procedure for estimating the molecular parameters for these overlapping absorption lines from quantitative reference spectra taken with the TDLAS instrument at different pressures and concentrations. The system was developed for the quantitation of gaseous constituents in a single puff of cigarette smoke and this paper will describe the procedure and some of the factors that influence the accuracy of quantitation for 1,3-butadiene, including the approach taken to minimize the adverse effects of the absorption due to propylene in the same spectral region.
Keywords:Pressure broadened half-width  1  3-Butadiene  Propylene  Tunable diode laser spectroscopy  Cigarette smoke