首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Voltammetric Determination of Pb(II) and Cd(II) Ions in Well Water Using a Sputtered Bismuth Screen‐Printed Electrode
Authors:Velia Sosa  Núria Serrano  Cristina Ariño  José Manuel Díaz‐Cruz  Miquel Esteban
Institution:Departament de Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1‐11, E–08028 – Barcelona, Spain phone: (34) 93?402?15?45, fax: (34) 93?402?12?33
Abstract:A method using commercially available sputtered bismuth screen‐printed electrodes (BispSPE), as substitute to mercury electrodes, for the determination of trace Pb(II) and Cd(II) ions in drinking well water samples collected in a contaminated area in The Republic of El Salvador by means of differential pulse anodic stripping voltammetry (DPASV) has been proposed. The comparable detection and quantification limits obtained for both BispSPE and hanging mercury drop electrode (HMDE), together with the similar results with a high reproducibility obtained in these water samples analyses recommend the applicability of BispSPE for the determination of low level of metal concentrations in natural samples.
Keywords:Bismuth sputtered electrodes  Screen‐printed electrodes  Stripping voltammetry  Metal ions