高动态范围激光等离子体诊断系统及其在惯性约束聚变实验中的应用
引用本文:曹柱荣,张海鹰,董建军,袁铮,缪文勇,刘慎业,江少恩,丁永坤.高动态范围激光等离子体诊断系统及其在惯性约束聚变实验中的应用[J].物理学报,2011,60(4):45212-045212.
作者姓名:曹柱荣  张海鹰  董建军  袁铮  缪文勇  刘慎业  江少恩  丁永坤
作者单位:中国工程物理研究院激光聚变研究中心,绵阳 621900
基金项目:国家自然科学基金(批准号10905050)资助的课题.
摘    要:基于高功率激光等离子体X射线辐射谱特性,设计和研制了一种大画幅高动态范围MCP选通型分幅相机. 单画幅宽度13mm,长度36mm,曝光时间0.5—5ns可调.与X射线CCD比较,系统在1.0—10keV的谱响应相对平整,无高能增强效应.利用高功率激光打靶实验进行了性能考核实验,结果表明,系统的信噪比明显好于X射线CCD系统,动态范围大于3×103. 系统已经在神光Ⅱ装置ICF物理实验中获得成功应用. 关键词: 动态范围 谱响应 激光等离子体诊断 分幅相机

关 键 词:动态范围  谱响应  激光等离子体诊断  分幅相机
收稿时间:2010-05-22
修稿时间:6/7/2010 12:00:00 AM

High dynamic range imaging and application to laser-plasma diagnostics in inertial confinement fusion (ICF) experiment
Cao Zhu-Rong,Zhang Hai-Ying,Dong Jian-Jun,Yuan Zheng,Miao Wen-Yong,Liu Shen-Ye,Jiang Shao-En,Ding Yong-Kun.High dynamic range imaging and application to laser-plasma diagnostics in inertial confinement fusion (ICF) experiment[J].Acta Physica Sinica,2011,60(4):45212-045212.
Authors:Cao Zhu-Rong  Zhang Hai-Ying  Dong Jian-Jun  Yuan Zheng  Miao Wen-Yong  Liu Shen-Ye  Jiang Shao-En  Ding Yong-Kun
Institution:Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China;Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang 621900, China
Abstract:High dynamic range and large format technique of micro-chanunel plate (MCP), gated framing camera is developed to diagnose high-power laser-plasma X-ray emission spectra. The single frame format is 13 mm×36 mm, and exposure time is adjustable from 0.5 ns to 5 ns. Its spectral response in 1.0—10 keV is more flat than that of X-ray charge-coupled device (CCD), and there exists no energetic enhancement effect. Performance evaluation has been conducted on high power laser devices, and the results show that the system has a high signal-to-noise ratio and the dynamic range is greater than 3 × 103. The system has been applied successfully to inertial confinement fusion (ICF) physics experiment.
Keywords:dynamic range  spectral response  laser-plasma diagnostics  framing camera
本文献已被 CNKI 万方数据 等数据库收录!