Two-dimensional residual charge density distribution measurement of surface leader |
| |
Authors: | Junbo Deng Lu Pu Haibao Mu Guanjun Zhang Shigeyasu Matsuoka Akiko Kumada Kunihiko Hidaka |
| |
Affiliation: | 1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi''an Jiaotong University, Xi''an 710049, China;2. The University of Tokyo, Department of Electrical Engineering, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan;3. Shaanxi Electric Power Research Institute, Xi''an, Shaanxi 710054, China |
| |
Abstract: | The charge density distribution of the surface leader has never been measured before. Because the surface leader usually covers a long distance, and the surface potential caused by leader discharge is usually very high, this creates difficulties in measuring the potential distribution of the surface leader. In this paper, with a feedback type electrostatic probe based on a field-nullify technique, a charge density distribution scanning system is developed. A two-layer structure pipe is designed to lower the surface potential after discharge. In this way, the surface potential distribution caused by the residual charge of the leader discharge under the application voltage as high as to 40 kV can be measured. The surface charge density distribution including the leader and streamer is perfectly measured, which is in good agreement with the photograph. |
| |
Keywords: | Residual charge density distribution Electrostatic probe Scanning system Surface discharge |
本文献已被 ScienceDirect 等数据库收录! |
|