阴阳离子双隔膜三室电解槽电渗析处理垃圾渗滤液
引用本文:陈日耀,陈震,耿亚敏,郑曦,陈晓.阴阳离子双隔膜三室电解槽电渗析处理垃圾渗滤液[J].应用化学,2009,26(11):1336-1340.
作者姓名:陈日耀  陈震  耿亚敏  郑曦  陈晓
作者单位:(1.福建师范大学化学与材料学院 福州 350007;2.宁德师范高等专科学校化学系 宁德 352100)
基金项目:福建省自然科学基金,福建省教育厅 
摘    要:采用阴阳离子双隔膜三室电解槽,将电渗析技术与Fenton试剂法结合,去除垃圾渗滤液中氨氮和CODCr。垃圾渗滤液中的氨氮通过电渗析技术富集到阴极液中,随后用化学沉淀法加以去除。同时,在铁阳极上生成的Fe2+离子,与滴加入阳极液中的H反应生成Fenton试剂,降解有机物,降低CODCr。实验结果表明,模拟废水中的氨氮透过率达80%,垃圾渗滤液中氨氮浓度和CODCr由原来的1982和2248 mg/L分别降至200和127 mg/L。

关 键 词:垃圾渗滤液  电渗析  Fenton  试剂  
收稿时间:2008-10-09
修稿时间:2009-06-09

Treatment of Landfill Leachates by Electrodialysis in Three-chamber Cell Divided by Two Membranes
CHEN Ri-Yao,CHEN Zhen,GENG Ya-Min,ZHENG Xi,CHEN Xiao.Treatment of Landfill Leachates by Electrodialysis in Three-chamber Cell Divided by Two Membranes[J].Chinese Journal of Applied Chemistry,2009,26(11):1336-1340.
Authors:CHEN Ri-Yao  CHEN Zhen  GENG Ya-Min  ZHENG Xi  CHEN Xiao
Institution:(1.College of Chemistry and Materials Science,Fujian Normal University,Fuzhou 350007; 2.Chemistry Department,Fujian Ningde Teachers College,Ningde 352100)
Abstract:Electrodialysis and Fenton reagent method were combined to decrease the concentration of NH4+-N and CODCr in landfill leachates by means of coupling membrane triple chamber cell. NH4+-N in landfill leachates was enriched in catholyte by electrodialysis, then removed by  chemical precipitation. In the meantime, Fe2+ was generated at the Fe anode.  H2O2 was dropped into the anolyte to produce Fenton reagent, which could degrade organic compounds and decrease the concentration of CODCr. The experimental results show that the removal rate of NH4+-N in simulated wastewater was up to 80% , and the concentrations of NH4+-N and CODCr in the landfill leachates were decreased from 1982 mg/L and 2248mg/L to 200mg/L and 127mg/L,respectively.  
Keywords:landfill leachates  electrodialysis  Fenton reagent