首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A multi-wall carbon nanotubes-dicetyl phosphate electrode for the determination of hypoxanthine in fish.
Authors:Shaofang Lü
Institution:Department of Chemistry, Xiaogan University, Xiaogan 432100, Hubei, China. lu_shaofang@163.com
Abstract:An enzymeless sensor based on a multi-walled carbon nanotubes-dicetyl phosphate (MWCNT-DCP) film modified vitreous carbon electrode was developed for the determination of hypoxanthine. The MWCNT-DCP film modified electrode showed a remarkable enhancement effect on the oxidation peak current of hypoxanthine. Under the optimized conditions, the oxidation peak current is proportional to the concentration of hypoxanthine over the range from 5.0 x 10(-7) to 2.0 x 10(-4) mol L(-1) with a detection limit (S/N = 3) of 2.0 x 10(-7) mol L(-1). The MWCNT-DCP film modified electrode has been successfully used to detect hypoxanthine in fish samples.