首页 | 本学科首页   官方微博 | 高级检索  
     


Ceria nanoparticles deposited on graphene nanosheets for adsorption of copper(II) and lead(II) ions and of anionic species of arsenic and selenium
Authors:Anna?Baranik,Anna?Gagor,Ignasi?Queralt,Eva?Marguí,Rafal?Sitko,Beata?Zawisza  author-information"  >  author-information__contact u-icon-before"  >  mailto:beata.zawisza@us.edu.pl"   title="  beata.zawisza@us.edu.pl"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author  author-information__orcid u-icon-before icon--orcid u-icon-no-repeat"  >  http://orcid.org/---"   itemprop="  url"   title="  View OrcID profile"   target="  _blank"   rel="  noopener"   data-track="  click"   data-track-action="  OrcID"   data-track-label="  "  >View author&#  s OrcID profile
Affiliation:1.Institute of Chemistry,University of Silesia,Katowice,Poland;2.Institute of Low Temperature and Structure Research, Polish Academy of Sciences,Wroc?aw,Poland;3.Department of Geosciences,Institute of Environmental Assessment and Water Research, IDAEA-CSIC,Barcelona,Spain;4.Department of Chemistry,University of Girona, Faculty of Sciences,Girona,Spain
Abstract:A nanocomposite prepared from graphene nanosheets and cerium nanoparticles (G/CeO2) was applied to the extraction of Se(IV), As(V), As(III), Cu(II) and Pb(II). The structure of G/CeO2 was investigated by scanning electron microscopy, X-ray diffraction and Raman spectroscopy. The optimal pH values for extraction are 4.0 for As(V), 3.0 for Se(IV), and 6.0 for both Cu(II) and Pb(II). The maximum adsorption capacity of G/CeO2 (expressed as mg·g?1) were calculated by the Langmuir model and are found to be 8.4 for As(V), 14.1 for Se(IV), 50.0 for Cu(II) and 75.6 for Pb(II). The sorbent was applied to dispersive solid phase microextraction prior to direct quantitation by energy-dispersive X-ray fluorescence spectrometry without the need for prior elution. The limits of detection (in ng·mL?1 units) are 0.10 for As(V), 0.11 for Se(IV), 0.19 for Cu(II) and 0.21 for Pb(II). The precisions (RSDs) are <4.5%. The accuracy of the method (1 - 4%) was verified by analysis of the certified reference material (CRM 1640a - natural water). The method was successfully applied in ultratrace element determination and to the speciation of selenium in environmental waters.
Graphical abstract The method gives possibility of simultaneous preconcentration and determination in environmental waters of both anionic (As(V) and Se(IV)) and cationic (Cu(II) and Pb(II)) forms of selected metals using graphene nanosheets and cerium nanoparticles. Se(IV) can be selective determined in the presence of Se(VI).
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号