Modulation of mobile phase composition in flow-injection/sequential-injection chromatography exploiting multisyringe flow analysis
Authors:Mailen Fernández  Manuel Miró  Hilda M González  Víctor Cerdà
Institution:(1) Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, 07122 Palma de Mallorca, Illes Balears, Spain;(2) Cuban Sugar Research Institute, Carretera al Central Martínez Prieto km 2.5, Boyeros, La Habana, Cuba;(3) Department of Quality Assurance and Pharmaceutical Technology, Food and Pharmaceutical Sciences Institute, University of Havana, Havana, Cuba
Abstract:In this paper, a time-based multicommutated flow system is proposed for appropriate selection and modulation of mobile phase composition in flow-injection (FI)/sequential-injection (SI) chromatography. The novel flow assembly involves the on-line coupling of a short monolithic reversed-phase chromatographic column with a multisyringe flow injection set-up furnished with a set of solenoid valves. The proposed hyphenated technique was applied to the simultaneous spectrophotometric determination of thiamine (B1), pyridoxine (B6) and cyanocobalamin (B12) which were taken as model analytes. The separation method capitalizes on a dual isocratic elution protocol involving the use of a single forward stroke of the multisyringe pump for initial delivery of 50 mmol L−1 ammonium acetate (pH 7.0) for 2.4 min followed by 50 mmol L−1 ammonium acetate–methanol (80:20, v/v) for 6.4 min at 0.5 mL min−1 and room temperature. Detection was performed at the maximum wavelength for each target vitamin—280 nm for B1, 325 nm for B6, and 360 nm for B12. A first-order, two-level full-factorial design was utilized to ascertain the significant variables influencing the chromatographic separation and the magnitude of the interaction effects. The experimental design method revealed that resolution of the target vitamins is highly dependent on the pH, percentage of organic modifier, and their second-order interaction. The multisyringe flow-injection-based monolithic column separation method, which should be viewed as an expeditious and cost-effective alternative to the high-performance liquid chromatography counterpart, was applied to the separation and determination of B1, B6, and B12 in different pharmaceutical dosage forms in less than 9 min. Statistical comparison of the results from the proposed procedure with those from the HPLC method endorsed by the US Pharmacopeia revealed there were no significant differences at the 95 % confidence level.
Keywords:Monolithic column  Multisyringe liquid chromatography  Pyridoxine  Thiamine  Cyanocobalamin  Pharmaceutical preparations
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号