(1) Dipartimento di Chimica Università di Firenze, Via della Lastruccia 3, 50019 Sesto Fiorentino (FI), Italy
Abstract:
The chlorite ion is an unavoidable by-product of the disinfection of drinking water by means of chlorine dioxide. The maximum concentration values of chlorite accepted in many countries regulations range from 0.2 to 1.0 mg L–1. A simple, inexpensive and quickly set up voltammetric procedure for the on-site determination of chlorite in drinking water networks is described. This procedure is suitable for the whole range of applications in drinking water plants. A useful cell for on-field analysis has been developed. Surface morphology and behaviour of carbon-based working electrodes have been investigated by voltammetry and atomic force microscopy (AFM). Actual samples of different types of water networks have been analysed for chlorite concentration.