首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Observations of water cavitation intensity under practical ultrasonic cleaning conditions
Authors:Niemczewski Bogdan
Institution:Tele- and Radio Research Institute, ul. Ratuszowa 11, 03-450 Warsaw, Poland. bniemcz@itr.org.pl
Abstract:In the industrial cleaning processes either organic solvents or water solutions are used as the cleaning media. The primary causative factor of ultrasonic cleaning is cavitation. Below are presented results of investigations into the influence of temperature, gas content and the solution level in an ultrasonic cleaner on cavitation intensity in the tap water. Previous investigations have revealed a great deal of information on the influence of the above factors on the cavitation intensity and these are confirmed. It has now been found that the tap water reaches the highest cavitation intensity at temperatures below 20 degrees C but during heating at higher temperatures (20-40 degrees C) a second peak of cavitation intensity may appear-depending on the height of water in the bath and air content.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏