首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Transient shear flow behavior of concentrated long glass fiber suspensions in a sliding plate rheometer
Authors:Kevin C OrtmanNeeraj Agarwal  Aaron PR EberleDonald G Baird  Peter WapperomA Jeffrey Giacomin
Institution:a Chemical Engineering Department, Virginia Tech, Blacksburg, VA 24061, United States
b Mathematics Department, Virginia Tech, Blacksburg, VA 24061, United States
c Rheology Research Center and Mechanical Engineering Department, University of Wisconsin, Madison, WI 53706, United States
Abstract:In order to eventually predict the behavior of long fiber suspensions in complex flows commonly found in processing operations, it is necessary to understand their rheology and its connection to the evolution of fiber orientation and configuration in well defined flows. In this paper we report the transient behavior at the startup of shear flow of a polymer melt containing long glass fibers with a length (L) >1 mm, using a sliding plate rheometer (SPR). The operation of the SPR was confirmed by comparing the transient shear viscosity (η+) for a polymer melt and a melt containing short glass fibers (L < 1 mm) with measurements obtained from a cone-and-plate device, using a modified sample geometry that was designed to avoid wall effects. For the long fiber systems, measurements could only be obtained in the SPR because these systems would not stay within the gap of the rotational rheometer. Transient stress growth behavior of the long fiber systems was obtained as a function of shear rate and fiber concentration for samples prepared with three different initial orientations. Results showed that, unlike short fiber systems (with a random planar initial orientation) that usually exhibit a single overshoot peak followed by a steady state, η+ of the long fiber suspensions often passed through multiple transient regions, depending on the fiber concentration and applied shear rate. Additionally, η+ of the long fiber suspensions was found to be highly dependent on the initial orientation of the sheared samples. Finally, the initial and final fiber orientations of the long glass fiber samples were measured and used to initiate an explanation of the viscosity behavior. The results obtained in this research will be useful for future assessment of a quantitative correlation between transient rheology and the evolution of fiber orientation.
Keywords:Long glass fiber  Sliding plate rheometer  Transient rheology  Orientation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号