Comparative measurements between NTD and GEL detectors for radon gas
Authors:G Espinosa  J I Golzarri  R B Gammage
Institution:

a Instituto de Física, UNAM. Apdo. Postal 20-364, México, D.F 01000, Mexico

b Oak Ridge National Laboratory, Oak PO Box 2008, Oak Ridge, TN 37831, USA

Abstract:Because of the interest in an inexpensive radon monitoring technique and the use of new materials and new methods, this work presents comparative measurements between traditional passive radon detector using nuclear track detector (NTD), and a new method based on the diffusion of radon gas in gels, measuring the quantity of the remainder radioactive solids by the analysis of the gamma radiation from the decay of radon daughters. The methodology of the new detectors is introduced. The preliminary results show a measurable response of the gel material detectors to radon gas. The measurements are compared with those using NTDs CR-39 type for calibration purposes. Both the detection systems, the passive close-end cup system with NTDs and the passive close-end cup gel material detector, were exposed at the same time in the radon calibration chamber to different radon exposition levels from 150 to 3000 Bq/m−3.
Keywords:Radon  Nuclear tracks  Gel detectors