首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Neutron and gamma ray doses from a 252Cf brachytherapy source in a water phantom
Authors:Ibahim Al-Saihati  A A Naqvi
Institution:1. Department of Electrical Engineering, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
2. Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
Abstract:Axial and radial doses of Neutrons and gamma rays from an Isotron 252Cf Brachytherapy source were calculated in a Water phantom using Maienshein’s prompt fission gamma rays data and Maxwellian neutron energy spectrum. It was observed that neutron dose due to the source casing thickness does not contribute significantly to the total dose. Further the calculated secondary gamma ray dose rate is very small compared to the calculated primary gamma dose rate. Neutron and secondary gamma ray dose calculated in this study agree with the published data. Results of this study will be presented here.