首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Interferometric tolerance determination for a Dove prism using exact ray trace
Authors:Enoch Gutierrez-Herrera  Marija Strojnik
Institution:Centro de Investigaciones en Optica, Apdo. Postal 1-948, C.P. 37000 Leon, Guanajuato, Mexico
Abstract:We use exact ray trace to calculate the interferometric Dove prism tolerance to manufacturing errors. We model the manufacturing errors by modifying the position of the prism vertices. The normal to the prism faces establishes the direction of the rays. We determine the prism tolerance by analyzing the optical traversed path rays. We evaluate the change in the image quality introduced by the normal deviation. When the manufacturing tolerance is maintained within ±0.35 arc sec, the maximum wave-front deviation is better than λ/10 at 633 nm. We found that a Dove prism with such tolerance introduces an OPD of two orders of magnitude lesser than a commercial Dove prism. The exact ray trace accuracy of the developed program is validated with the commercially available optical-design program OSLO™. The calculated tolerance complements a previous analysis of a Dove prism for its implementation in a rotationally shearing interferometer.
Keywords:Dove prism  Manufacturing errors  Tolerance  Exact ray trace  Rotationally shearing interferometer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏