Exploiting the bead injection LOV approach to carry out spectrophotometric assays in wine: application to the determination of iron |
| |
Authors: | Vidigal Susana S M P Tóth Ildikó V Rangel António O S S |
| |
Affiliation: | a CBQF/Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal b REQUIMTE, Departamento de Química, Faculdade de Farmácia, Universidade do Porto, Rua Aníbal Cunha 164, 4090-030 Porto, Portugal |
| |
Abstract: | A sequential injection lab-on-valve (SI-LOV) system was used to develop a new methodology for the determination of iron in wine samples exploiting the bead injection (BI) concept for solid phase extraction and spectrophotometric measurement. Nitrilotriacetic Acid (NTA) Superflow resin was used to build the bead column of the flow through sensor. The iron (III) ions were retained by the bead column and react with SCN− producing an intense red colour. The change in absorbance was monitored spectrophotometrically on the optosensor at 480 nm. It was possible to achieve a linear range of 0.09-5.0 mg L−1 of iron, with low sample and reagent consumption; 500 μL of sample, 15 μmol of SCN−, and 9 μmol of H2O2, per assay. The proposed method was successfully applied to the determination of iron in wine, with no previous treatment other than dilution, and to other food samples. |
| |
Keywords: | Solid phase spectrometry Sequential injection lab-on-valve Bead injection Iron Wine |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|