Standardization of125I by the sum-peak method and the results of a bilateral comparison between ENEA (Italy) and INP (Albania) |
| |
Authors: | P De Felice Xh Myteberi |
| |
Institution: | (1) ENEA Dip. Ambiente, Centro CASACCIA, Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, P. O. Box 2400, I-00100 Roma, Italy;(2) Institute of Nuclear Physics, Tirana, Albania |
| |
Abstract: | An intercomparison on absolute activity measurements of125I sources by the sumpeak method was carried out in 1993 between the Primary Standard Laboratories for Ionizing Radiations of Italy (ENEA) and Albania (INP). The sources were prepared by ENEA starting from a125I solution. The sources were measured at ENEA and successively at INP. The results were in good agreement, the deviation of the INP results from the ENEA results being about –0.5% with an overall uncertainty of both results about 0.3% (1). This paper describes the instrumentation and the experimental procedures used in this comparison by the two Institutes. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|