首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱-荧光检测法测定人血浆中匹伐他汀的含量
引用本文:OJHA Ashwini,GUTTIKAR Swati,VAYEDA Chintan,PADH Harish. 高效液相色谱-荧光检测法测定人血浆中匹伐他汀的含量[J]. 色谱, 2007, 25(5): 715-718
作者姓名:OJHA Ashwini  GUTTIKAR Swati  VAYEDA Chintan  PADH Harish
作者单位:B.V.Patel, Pharmaceutical Education & Research Development (PERD) Centre, Ahmedabad, Gujarat, India
摘    要:
 Pitavastatin belongs to the class of coenzyme A reductase inhibitors. Very few methods of assaying pitavastatin from human plasma are available in literature. An analytical method is presented for the determination of the drug from human plasma making use of the fluorescent property of the drug. The drug is extracted from plasma using ethyl acetate under neutral condition and then analyzed by reversed-phase high performance liquid chromatography (HPLC) with fluorescence detection (λEx 245 nm; λEm 420 nm). Analysis of pitavastatin was carried out on a C18 HPLC column using a gradient flow of mobile phase (0.01 mol/L monobasic potassium phosphate (pH 3.20)-acetonitrile, 63∶37, v/v). Fluorescein isothiocyanate was used as internal standard. The dynamic range of assay was 3 to 50 ng/mL. The intraday precision was less than 10% and accuracy ranged from 95.2% to 112.6%. The same for interday check was less than 12% and 92.8% to 105.1%, respectively. The drug was found to be stable under the assay conditions. The developed method is simple, precise, accurate, and stable. This indicates that it can be applied to routine analysis of this drug in human subjects where there are large numbers of samples without the need of specialized instruments like column switching.

关 键 词:fluoresceinisothiocyanate  fluorescencedetection  humanplasma  pitavastatin  highperformanceliquidchromatography(HPLC)  
文章编号:1000-8713(2007)05-0715-04
收稿时间:2007-05-08
修稿时间:2007-05-08

Determination of Pitavastatin from Human Plasma Using High Performance Liquid Chromatography with Fluorescence Detection
OJHA Ashwini,GUTTIKAR Swati,VAYEDA Chintan,PADH Harish. Determination of Pitavastatin from Human Plasma Using High Performance Liquid Chromatography with Fluorescence Detection[J]. Chinese journal of chromatography, 2007, 25(5): 715-718
Authors:OJHA Ashwini  GUTTIKAR Swati  VAYEDA Chintan  PADH Harish
Affiliation:B.V.Patel, Pharmaceutical Education & Research Development (PERD) Centre, Ahmedabad, Gujarat, India
Abstract:
Pitavastatin belongs to the class of coenzyme A reductase inhibitors. Very few methods of assaying pitavastatin from human plasma are available in literature. An analytical method is presented for the determination of the drug from human plasma making use of the fluorescent property of the drug. The drug is extracted from plasma using ethyl acetate under neutral condition and then analyzed by reversed-phase high performance liquid chromatography (HPLC) with fluorescence detection (lambda(Ex) 245 nm; lambda(Em) 420 nm). Analysis of pitavastatin was carried out on a C18 HPLC column using a gradient flow of mobile phase (0.01 mol/L monobasic potassium phosphate (pH 3.20) -acetonitrile, 63:37, v/v). Fluorescein isothiocyanate was used as internal standard. The dynamic range of assay was 3 to 50 ng/mL. The intraday precision was less than 10% and accuracy ranged from 95.2% to 112.6%. The same for interday check was less than 12% and 92.8% to 105.1%, respectively. The drug was found to be stable under the assay conditions. The developed method is simple, precise, accurate, and stable. This indicates that it can be applied to routine analysis of this drug in human subjects where there are large numbers of samples without the need of specialized instruments like column switching.
Keywords:high performance liquid chromatography (HPLC)  fluorescence detection  fluorescein isothiocyanate  pitavastatin  human plasma
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号