Application of fission track technique for estimation of uranium concentration in drinking waters of Punjab
Authors:S P Prabhu  P D Sawant  S S Raj  A Kumar  R M Tripathi  P K Sarkar
Institution:1. Health Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
2. Environmental Assessment Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
Abstract:Drinking water samples were collected from four different districts, namely Bhatinda, Mansa, Faridkot and Firozpur, of Punjab for ascertaining the U(nat.) concentrations. All samples were preserved, processed and analyzed by laser fluorimetry (LF). To ensure accuracy of the data obtained by LF, few samples (10 nos) from each district were analyzed by alpha spectrometry as well as by fission track analysis (FTA) technique. For FTA technique few μl of water sample was transferred to polythene tube, lexan detector was immersed in it and the other end of the tube was also heat-sealed. Two samples and one uranium standard were irradiated in DHRUVA reactor. Irradiated detectors were chemically etched and tracks counted using an optical microscope. Uranium concentrations in samples ranged from 3.2 to 60.5 ppb and were comparable with those observed by LF.