首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Method development for separating organic carbonates by ion‐moderated high‐performance liquid chromatography
Authors:Chin Li Cheung
Institution:Department of Chemistry, University of Nebraska‐Lincoln, Lincoln, NE, USA
Abstract:An ion‐moderated partition high‐performance liquid chromatography method was developed for the separation and identification of common organic carbonates. The separation of organic carbonates was achieved on an ion exclusion column with an exchangeable hydrogen ion. An isocratic, aqueous mobile phase was used for elution and detection was performed with a refractive index detector. The developed method was validated for specificity, linearity, limits of detection and quantification, precision and accuracy. All calibration curves showed excellent linear regression (R2 > 0.9990) within the testing range. The limits of detection were 3.8–30.8 ppm for the analyzed carbonates. Improvements in the peak resolution of the chromatograms were achieved by decreasing the column temperature. Addition of the organic modifier, acetonitrile, to the eluent was found to have insignificant effects on the peak resolution. The developed method was demonstrated for analyzing organic carbonate components in the electrolyte system of a commercial lithium ion battery.
Keywords:High‐performance liquid chromatography  Lithium ion batteries  Method development  Organic carbonates