首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparison of the compact dry EC with the most probable number method (AOAC official method 966.24) for enumeration of Escherichia coli and coliform bacteria in raw meats. Performance-Tested Method 110402
Authors:Kodaka Hidemasa  Mizuochi Shingo  Teramura Hajime  Nirazuka Tadanobu
Institution:Nissui Pharmaceutical Co. Ltd., 1075-2, Hokunanmoro, Yuki, Ibaraki 307-0036, Japan. h-kodaka@yki.nissui-pharm.jp
Abstract:Compact Dry E. coli/Coliform Count (EC) is a ready-to-use test method for the enumeration of Escherichia coli and coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated onto the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35 degrees C for 20-24 h and the colonies counted without any further working steps. The Compact Dry EC medium plates were validated as an analysis tool for determining colony-forming units (CFU) of E. coli and coliform bacteria from a variety of raw meats using 5 different types of raw meats. The performance tests were conducted at 35 degrees C. In all studies performed, no apparent differences were observed between the Compact Dry EC method and the AOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.93 (E. coli) and r2 = 0.93 (coliform bacteria) could be assigned, as stated in the application for "Performance-Tested Method."
Keywords:
本文献已被 PubMed 等数据库收录!