Sample enrichment by using monolithic precolumns in microcolumn liquid chromatography |
| |
Authors: | Lim Lee Wah Hirose Katsuaki Tatsumi Shinichi Uzu Hideyuki Mizukami Megumi Takeuchi Toyohide |
| |
Affiliation: | Department of Chemistry, Faculty of Engineering, Gifu University, 1-1 Yanagido, Gifu 501-1193, Japan. |
| |
Abstract: | An on-line sample enrichment system was designed using monolithic precolumns in microcolumn LC. The monolithic ODS capillary columns were prepared via in situ sol-gel processes. The enrichment efficiency of the monolithic columns was tested by using phthalates as the analytes. The relative standard deviations (n = 6) for the retention time, peak area and peak height were between 0.4 and 1.2%, 0.9 and 5.5% and 0.4 and 3.9%, respectively. The system was linear (R2 > 0.99) within the working sample concentration and sample volume ranges. Comparing to 0.2 microl injection with a typical sample injector, the theoretical plate number of a same separation column was increased by 3-6-fold when the precolumn unit was used for sample injection. The recoveries of the analytes were between 88 and 120%, and the sample volume that could be injected into the system was increased up to 5000-fold. The limits of detection were improved by more than 2000-fold and were between 0.21 and 0.87 ng ml(-1) even with a UV absorbance detector. This system was applied to the determination of phthalates contained in laboratory distilled water and tap water samples. |
| |
Keywords: | Sample enrichment Monolithic precolumns Water analysis Phthalates |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|