Effect of poly (ethylene glycol) coating on the magnetic and thermal properties of biocompatible magnetic liquids
Authors:Arkadiusz Józefczak  Tomasz Hornowski  Miko?aj ?abowski  Peter Kop?anský  Andrzej Szlaferek
Institution:a Institute of Acoustics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań, Poland
b Institute of Experimental Physics, Slovak Academy of Sciences, Watsonova 47, 040 01 Košice, Slovakia
c Institute of Molecular Physics, PAS, Smoluchowskiego 17, 60-179 Poznań, Poland
Abstract:The aim of this study was to investigate the influence of poly(ethylene glycol) surface-active coating on the magnetic and thermal properties of biocompatible magnetic liquids. The data were analyzed using the high-temperature approximation model taking into account polydispersity of a system. Heating ability of the PEG-stabilized magnetic fluids was determined by the calorimetric measurement of specific absorption rate (SAR) at a frequency of 750 kHz and a magnetic field of 0-2 kA/m. MF-Oleate/PEG heating properties were found to be comparable to the ones of MF-Oleate. The PEG shell thus does not seem to effect the thermal characteristics and SAR values and might make the magnetic fluid useful for application in hyperthermia treatment.
Keywords:Magnetic liquid  Biocompatibility  Hyperthermia  Magnetization