Development of quantitative vitellogenin-ELISAs for fish test species used in endocrine disruptor screening
Authors:Bente M Nilsen  Karin Berg  Janne K Eidem  Sven-Inge Kristiansen  François Brion  Jean-Marc Porcher  Anders Goksøyr
Institution:(1) Biosense Laboratories AS, Thormøhlens gt. 55, 5008 Bergen, Norway;(2) INERIS (Institut National de lrsquoEnvironnement Industriel et des Risques), Unité drsquoEvaluation des Risques Ecotoxicologiques, BP2, 60550 Verneuil en Halatte, France;(3) Department of Molecular Biology, University of Bergen, HIB, P.O. Box 7800, 5020 Bergen, Norway
Abstract:The yolk protein precursor vitellogenin (Vtg) in plasma has proved to be a simple and sensitive biomarker for assessing exposure of fish to environmental estrogens. Within international bodies such as the Organization for Economic Cooperation and Development (OECD) work is ongoing to develop screening and testing programmes for endocrine disrupting effects of new chemicals, and in the focus of this development are the fish test species common carp (Cyprinus carpio), fathead minnow (Pimephales promelas), zebrafish (Danio rerio) and Japanese medaka (Oryzias latipes). In this study we have developed quantitative enzyme linked immunosorbent assays (ELISAs) for Vtg in common carp/fathead minnow, zebrafish and Japanese medaka. The assays were developed using a combination of monoclonal and polyclonal fish Vtg antibodies in a sandwich format, using stabilized Vtg from the test species as a standard. The carp Vtg ELISA has a working range of 1–63 ng/mL, a minimal detection limit of 0.6 ng/mL, and may also be used for quantification of Vtg in fathead minnow. In fathead minnow whole-body homogenate samples, the practical detection limit is 400 ng/mL due to the matrix effect. The zebrafish Vtg ELISA has a working range of 0.5–63 ng/mL, a minimal detection limit of 0.4 ng/mL, and a practical detection limit of 200 ng/mL in whole-body homogenate samples. The medaka Vtg ELISA has a working range of 0.25–16 ng/mL, a minimal detection limit of 0.1 ng/mL, and a practical detection limit of 125 ng/mL in whole-body homogenate samples. The intra- and inter-assay variations were below 20% for all assays. The assays were evaluated with sets of representative samples spanning the wide dynamic range of Vtg-levels found in fish exposed to environmental estrogens, and all three assays are currently undergoing international inter-laboratory validation.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号