Abstract: | ![]() In this study a novel technique for 2D spray temperature measurement is presented. For this purpose the thermographic phosphor (TP) Mg4GeO5.5F:Mn was dispersed in n-dodecane and atomised using a conventional semi solid-cone nozzle. The thermographic phosphor was excited electronically by a frequency tripled Nd:YAG laser (355 nm). An ICCD-camera in combination with an image doubler detected the subsequently emitted phosphorescence at both peak emission wavelengths located at 633 nm and 659 nm, respectively. Utilising suitable calibration measurements, the local spray temperature was determined by evaluating the intensity ratio of both emission wavelengths. To the knowledge of the authors this is the first approach of spray temperature measurement exploiting the temperature dependent intensity ratio of thermographic phosphors. PACS 07.20.Dt; 32.50.+d |
| |