High repetition rate plasma mirror for temporal contrast enhancement of terawatt femtosecond laser pulses by three orders of magnitude
Authors:C Rödel  M Heyer  M Behmke  M Kübel  O Jäckel  W Ziegler  D Ehrt  M C Kaluza  G G Paulus
Institution:1.Institut für Optik und Quantenelektronik,Friedrich-Schiller-Universit?t Jena,Jena,Germany;2.Institut für Laser- und Plasmaphysik,Heinrich-Heine-Universit?t Düsseldorf,Düsseldorf,Germany;3.Otto-Schott-Institut für Glaschemie,Friedrich-Schiller-Universit?t Jena,Jena,Germany;4.Helmholtz Institut Jena,Jena,Germany
Abstract:We present a plasma mirror configuration that improves the temporal pulse contrast of femtosecond terawatt laser pulses by a factor of thousand using a single antireflection coated glass target. The device provides ultra-high contrast for experiments with a maximum repetition rate of 10 Hz. A third-order cross-correlator has been used to measure the temporal pulse contrast for several different plasma mirror targets. It is shown that the ASE can be suppressed to a level of 10−11. A comparison between a triggered and an untriggered plasma mirror reveals differences in the intensity distribution of the focused beam. The triggered plasma mirror produces a slightly larger focus due to the expansion of the triggered plasma mirror at −3 ps before the main pulse. We propose a cost-effective AR-coated and a blank glass target to reduce the costs of the consumable target material. High-harmonic radiation on solid surfaces has been generated with different plasma mirror targets to demonstrate the high laser contrast.
Keywords:
本文献已被 SpringerLink 等数据库收录!