摘    要:对用氢化物发生原子荧光光谱法联合测定水中砷、硒的测量结果进行了不确定度评定。分析了测量不确定度的来源,如标准物质、样品取样体积、样品稀释体积、工作曲线的非线性及测量结果的重复性,对各不确定度分量进行了评定和计算。砷、硒含量测量的扩展不确定度均为5.28%。

关 键 词:原子荧光光谱法  不确定度      测定
修稿时间:2007-03-01

MEASUREMENT UNCERTAINTY OF ARSENIC AND SELENIUM IN WATER BY ATOMIC FLUORESCENCE SPECTROMETRY
Yang Xiulin,Liu Hongwu. MEASUREMENT UNCERTAINTY OF ARSENIC AND SELENIUM IN WATER BY ATOMIC FLUORESCENCE SPECTROMETRY[J]. Chemical Analysis And Meterage, 2007, 16(3): 7-10
Authors:Yang Xiulin  Liu Hongwu
Abstract:The uncertainty of measurement for the determination of arsenic and selenium in water by hydride generation atomic fluorescence spectrometry was evaluated. The uncertainty caused by the certified reference material, solution volume, standard curve, repeatability of results of measurements were evaluated and calculated respectively. The expanded uncertainly of measurement for Se,As were both of 5.28%.
Keywords:atomic fluorescence spectrometry   uncertainty   arsenic   selenium   determination