首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Liver imaging at 1.5 tesla: pulse sequence optimization based on improved measurement of tissue relaxation times
Authors:K J Van Lom  J J Brown  W H Perman  J C Sandstrom  J K Lee
Institution:Scripps Memorial Hospital, Chula Vista, California 92012.
Abstract:In order to predict the most sensitive MR imaging sequence for detecting liver metastases at 1.5 T, in vivo measurements of T1 and T2 relaxation times and proton density were obtained using multipoint techniques. Based on these measurements, two-dimensional contrast contour plots were constructed demonstrating signal intensity contrast between hepatic lesions and surrounding liver parenchyma for different pulse sequences and pulse timing parameters. The data predict that inversion recovery spin echo (IRSE) imaging should yield the greatest contrast between liver metastases and liver parenchyma at 1.5 T, followed by short tau inversion recovery (STIR) and spin-echo (SE) pulse sequences. T2-weighted SE images provided greater liver/lesion contrast than T1-weighted SE pulse sequences. Calculated T1, T2, and proton density values of the spleen were similar to those of hepatic metastatic lesions, indicating that the signal intensity of the spleen may be used as an internal standard to predict the signal intensity of hepatic metastases on T1- and T2-weighted images at 1.5 T.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏