首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A New Neutral Carrier for Silver Ions Based on a Bis(Thiothiazole) Derivative and its Evaluation in Membrane Electrodes
Authors:Ibrahim H A Badr
Institution:(1) Department of Chemistry, Faculty of Science, Ain Shams University, P.O. Box 11566, Cairo, Egypt
Abstract:Membrane electrodes based on 2,2prime-dithiobis(benzothiazole), DTBBT, as a neutral carrier for silver ions are described. Silver-selective membrane electrodes formulated with 2thinspwt% DTBBT ionophore and 50thinspmol% TFPB in an FPNPE plasticized poly (vinyl chloride) exhibited near-Nernstian responses towards silver ions (60.3±0.5mVthinspdecade–1) over a wide silver ion activity range of 0.83thinspµM to 94thinspmM. Increasing the amount of anionic sites, TFPB, to 100 or 150thinspmol% (relative to the DTBBT weight) resulted in super-Nernstian responses toward silver ions. Membrane electrodes prepared using a low dielectric constant plasticizer, however, exhibited sub-Nernstian responses. Polymer membrane electrodes with optimal composition (i.e., 2thinspwt% DTBBT, 50thinspmol% TFPB in FPNPE plasticized poly(vinyl chloride)) exhibited high potentiometric selectivity towards silver ions over alkali, alkaline earth, transition metal ions, as well as heavy metal ions such as Hg2+ and Pb2+. A good correlation was found between the potentiometric selectivity coefficients and the change in the UV-visible spectra of the ionophore upon exposure to different metal ions. The overall performance of the silver-selective membrane electrodes based on DTBBT ionophore, which is available at low cost, was found to be comparable to the performance of silver electrodes prepared with Fluka silver ionophore-IV. A DTBBT-based silver electrode was used as an indicator electrode for titrations of silver ions using standard sodium chloride solutions. Sharp inflections occur at the end point, and the data obtained showed 99.4% recovery with a standard deviation of 0.7% (n=3). In addition, the applicability of the DTBBT-based silver-selective electrode is illustrated by measuring the silver concentrations in natural water spiked with silver nitrate and by analyzing the silver in electroplating wastewater samples. The results obtained utilizing a DTBBT-based silver electrode showed very good agreement with the standard methods of analysis.
Keywords:: Membrane electrodes  ion-selective electrodes  silver ionophores  bis(thiothiazole)  wastewater analysis  
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号