首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurements of actinide nuclides in water samples from the primary circuit of a nuclear power plant
Authors:G Rosner
Institution:(1) Institut für Strahlenschutz, Gesellschaft für Strahlen-und Umweltforschung mbH München, D-8042 Neuherberg, FRG
Abstract:Weekly, consecutive primary coolant samples from a boiling water reactor have been analyzed for239, 240Pu,238Pu+241Am,242Cm and244Cm for about two years, and for238Pu,241Pu and241Am for one year. Concentration ranges are reported. Samples were prepared for counting either directly by evaporation or by chemical separation on BioRad AG 1×4 resin and subsequent electrolysis, and were counted in 20 cm dia Frish grid ionization chambers. Procedures are described. For most actinide nuclides, activity ratios in primary coolant were found to be different from those in worldwide fallout, thus allowing an identification of origin in the case, that actinides should be detected in the vicinity of a nuclear power station.