首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analysis of dissolution test sample solutions by high speed capillary electrophoresis
Authors:K D Altria  E Traylen  N Turner
Institution:(1) Glaxo Research and Development, Pharmacy Division, Park Road, SG12 ODP Ware, Herts, UK
Abstract:Summary The quantitative use of high speed capillary electrophoresis (HSCE) is examined by applying high voltages across short capillaries. Acceptable performance in terms of injection precision and migration times were achieved within 1–2 minute analysis times. HSCE was used for the novel CE application of dissolution test sample solution analysis. The results generated by HSCE compared well with those generated using validated on-line UV absorbance measurements. It is concluded that HSCE is a viable alternative and supplement to standard analytical methods employed in dissolution test analysis.
Keywords:Capillary electrophoresis  High speed analysis  Dissolution testing  Pharmaceuticals
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏