Trace-matrix separations for high-purity chromium,molybdenum and tungsten with cellulose collectors |
| |
Authors: | Wilhelm Blödorn Robert Krismer Hugo M. Ortner Jens Stummeyer Peter Wilhartitz Gerold Wünsch |
| |
Affiliation: | (1) Institut für Anorganische Chemie, Universität Hannover, Callinstrasse 9, D-3000 Hannover 1, Federal Republic of Germany;(2) Metallwerk Plansee GmbH, A-6600 Reutte/Tyrol, Austria |
| |
Abstract: | ![]() Trace metals (20 elements) in high-purity chromium, molybdenum and tungsten are collected and preconcentrated by precipitation and adsorption on cellulose collectors. The compound methods allow the application of AAS and ICP-AES as determination methods for the production control of highly pure refractory metals under routine conditions.Presented in part at the 1989 European Winter Conference on Plasma Spectrochemistry, Reutte, Austria |
| |
Keywords: | high purity Cr Mo and W separation of matrix preconcentration of trace metals cellulose collectors ICP AAS |