首页 | 本学科首页   官方微博 | 高级检索  
     

ICP-MS测定淀粉铝含量的不确定度评定及改进方法
引用本文:高瑞峰,高孟朝,凌睿,张宁. ICP-MS测定淀粉铝含量的不确定度评定及改进方法[J]. 光谱学与光谱分析, 2016, 36(4): 1211-1216. DOI: 10.3964/j.issn.1000-0593(2016)04-1211-06
作者姓名:高瑞峰  高孟朝  凌睿  张宁
作者单位:1. 南京师范大学物理科学与技术学院,江苏 南京 210023
2. 南京市产品质量监督检验院,江苏 南京 210019
3. 南京市食品药品监督检验院,江苏 南京 210038
基金项目:国家科技支撑计划(2011BAK21B05),江苏省博士后科研资助计划项目(1202029C),质检公益性行业科研专项(201410167),南京市质量技术监督局重点科技项目(kj2012007)
摘    要:
测量不确定度,表征合理地赋予被测量之值的分散性。应用ISO/IEC Guide 98: 1993 Guide to the expression of uncertainty in measurement(简称GUM方法)的自下而上的策略进行测量不确定度的评定,剖析完整的分析测量过程,可以找出影响测量结果准确性的主要因素;采取针对性的措施,设法消除或降低这些因素的影响,可以改进测量方法。以电感耦合等离子体质谱法测定淀粉和面包糠中铝含量为例,其不确定度来源于测量重复性、最小二乘法拟合工作曲线的过程、标准储备液及其分取稀释过程的不确定度、溶液体积及样品称量过程的不确定度。经过各不确定度分量的评定,得知主要分量是由最小二乘法拟合工作曲线引入的相对标准不确定度urel(cAl)1,其次是由配制标准溶液系列的稀释过程引入的相对标准不确定度urel(cAl)3、由测量结果的重复性引入的相对标准不确定度urel(rep)。因此,采取较高灵敏度的质谱工作模式、增加测定次数、合理选取校准曲线的系列浓度点数值、选用相对误差较小的量器等措施进行方法改进。改进之后,三个主要分量urel(cAl)1urel(cAl)3urel(rep)分别从(0.035 8,0.013 2,0.008 5)降为(0.006 0,0.010 5和0.003 3),铝量的合成相对标准不确定度从0.039降为0.013,扩展不确定度从1.8 mg·kg-1降为0.4 mg·kg-1(k=2),效果显著。

关 键 词:测量不确定度  化学分析  方法改进  电感耦合等离子体质谱法    
收稿时间:2015-01-13

Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS
GAO Rui-feng,GAO Meng-chao,LING Rui,ZHANG Ning. Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS[J]. Spectroscopy and Spectral Analysis, 2016, 36(4): 1211-1216. DOI: 10.3964/j.issn.1000-0593(2016)04-1211-06
Authors:GAO Rui-feng  GAO Meng-chao  LING Rui  ZHANG Ning
Affiliation:1. Department of Physics, Nanjing Normal University, Nanjing 210023, China2. Nanjing Institute of Product Quality Inspection, Nanjing 210019, China3. Nanjing Institute for Food and Drug Control, Nanjing 210038, China
Abstract:
The measurement uncertainty is a non‐negative parameter associated with the result of a measurement that characteri‐zes the dispersion of the quantity values that could reasonably be attributed to the measurand .In the present study measurement uncertainty is estimated using the GUM (ISO/IEC Guide 98 :1993 Guide to the expression of uncertainty in measurement ) bot‐tom‐up approach .The steps were followed :specifying the measurand ;identifying all the associated sources of uncertainty ;quantifying the uncertainty components ;combining the uncertainty components ;determining the extended combined standard uncertainty ;reviewing the estimates and reporting the measurement uncertainty .In this process ,the major uncertainty compo‐nents with greater impact were identified ;try to eliminate or to reduce the impact of these components can improve measurement methods .Examples were the determination of aluminum in starch and bread crumbs by inductively coupled plasma‐mass spec‐trometry (ICP‐MS) .The uncertainties of aluminum contents were from measurement repeatability ,variability of calibration curve ,standard stock solution ,dilution ,solution volume and sample weighing .The data indicated that the major contributions to the uncertainty budget originating from urel (cAl )1 (the relative standard uncertainty of aluminum content derived from linear least squares calibration) ,urel (cAl )3 (the relative standard uncertainty of aluminum content derived from the dilution of the stand‐ard stock solutions ) and urel (rep) (the relative standard uncertainty derived from the repeatability ) .Based on the analysis of the main individual contributions of each uncertainty source to the total uncertainty value ,several modifications were proposed . Firstly helium collision mode was replaced by no gas mode to improve the sensitivity of mass spectrometry .Secondly the number of measurements was increased .Thirdly let the mean of data points in the calibration closer the measurand .Finally the relative error smaller gauges were used .After these modifications ,urel (cAl )1 ,urel (cAl )3 and urel (rep) were from (0.035 8 ,0.013 2 , 0.008 5) down to (0.006 0 ,0.010 5 ,0.003 3) ,respectively ;the combined relative standard uncertainty of aluminum was from 0.039 down to 0.013 ;the expanded uncertainty from 1.8 down to 0.4 mg · kg -1 (coverage factor k= 2) .The improvement effect was significant .
Keywords:Measurement uncertainty  Chemical analysis  Improvement  ICP-MS  Aluminum
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号