Simultaneous measurements of equivalence ratio and flame structure in multipoint injectors using PLIF |
| |
Authors: | Mikaë l Orain, Fr d ric Grisch, Eric Jourdanneau, Bjorn Rossow, Christian Guin,Brigitte Tr tout |
| |
Affiliation: | aOffice national d'études et de recherches aérospatiales, chemin de la Hunière, 91761 Palaiseau cedex, France |
| |
Abstract: | Simultaneous measurements of PLIF-kerosene and PLIF-OH have been successfully performed in a multipoint injection system for various overall equivalence ratio, air inlet temperature between 480 and 730 K and pressure up to 2.2 MPa. Single shot 2D-maps of the spatial distribution of kerosene vapour and OH radical in the combustor have been recorded with good signal-to-noise ratio. Results show that depending on the split between the pilot and the main injectors, the flame front exhibits a single or a double structure. Good spatial correlation between the repartition of the kerosene vapour and the position of the flame front was observed; in particular, no “dark zone” is observed between the fuel and the flame front. As temperature and pressure increase, fuel evaporation improves and the spatial distribution of OH radical becomes more homogeneous in the combustor, suggesting a partially-distributed combustion. To cite this article: M. Orain et al., C. R. Mecanique 337 (2009). |
| |
Keywords: | Combustion Planar laser-induced fluorescence Aromatics Kerosene– air combustion Flame structure High pressureMots-clé s: Combustion Imagerie de fluorescence induite par laser Aromatiques Combustion ké rosè ne– air Structure de flamme Haute pression |