Simultaneous measurements of equivalence ratio and flame structure in multipoint injectors using PLIF
Authors:Mikaë  l Orain, Fr  d  ric Grisch, Eric Jourdanneau, Bjorn Rossow, Christian Guin,Brigitte Tr  tout
Affiliation:aOffice national d'études et de recherches aérospatiales, chemin de la Hunière, 91761 Palaiseau cedex, France
Abstract:Simultaneous measurements of PLIF-kerosene and PLIF-OH have been successfully performed in a multipoint injection system for various overall equivalence ratio, air inlet temperature between 480 and 730 K and pressure up to 2.2 MPa. Single shot 2D-maps of the spatial distribution of kerosene vapour and OH radical in the combustor have been recorded with good signal-to-noise ratio. Results show that depending on the split between the pilot and the main injectors, the flame front exhibits a single or a double structure. Good spatial correlation between the repartition of the kerosene vapour and the position of the flame front was observed; in particular, no “dark zone” is observed between the fuel and the flame front. As temperature and pressure increase, fuel evaporation improves and the spatial distribution of OH radical becomes more homogeneous in the combustor, suggesting a partially-distributed combustion. To cite this article: M. Orain et al., C. R. Mecanique 337 (2009).
Keywords:Combustion   Planar laser-induced fluorescence   Aromatics   Kerosene–  air combustion   Flame structure   High pressureMots-clé  s: Combustion   Imagerie de fluorescence induite par laser   Aromatiques   Combustion ké  rosè  ne–  air   Structure de flamme   Haute pression