Abstract: | Experiments were performed on the condensation of steam from steam-air mixtures in annular flow at a cooled inner tube. The range of investigation was varied for laminar and turbulent flow for 1.5 × 103 Re 1.3 × 104 and inlet concentrations 0.59 psteam/ptotal 0.95. The measurements, performed at an open test loop at ptotal ≈ 0.96 bar, allowed local heat and mass transfer coefficients to be evaluated for various inlet lengths in the 2 m long annulus. The steam concentration was measured locally inside the annulus with a newly developed dew-point probe. The heat flux was measured locally using the temperature gradient in the cooled inner tube. Near the inlet region the experiments showed a slightly higher heat flux at the bottom of the tube compared to the top, although it is expected to be smaller there owing to a thicker liquid film. Far downstream from the inlet region the heat transfer at the top was higher than at the bottom. The reasons for these effects are discussed, yielding a better understanding of the thermal and fluid processes involved in condensation from vapor-gas mixtures. The measured data allow the development of correlations for predicting the local Nusselt and Sherwood numbers in a horizontal annular-flow chanbel. |