Optimal design of diffusive samplers
Authors:Underhill D W
Affiliation:Department of Environmental Health Sciences, School of Public Health, University of South Carolina, Columbia, SC 29208, USA.
Abstract:
Some commercially available diffusive samplers use two layers of adsorbent placed in series. After sampling is completed, the time weighted average concentration of analyte is estimated from the weighted sum of the uptake of analyte on these two layers. It is known that such a division into layers can increase the permissible sampling time. Here the principles underlying this sampling procedure are analyzed through a fundamental application of the theory of diffusion. Using a trial and error procedure, the optimal division of adsorbent was calculated, and the increase in sampling time that such a division can give was confirmed theoretically. Also, should the uptake in the backup layer exceed a predetermined fraction of the total uptake, this will indicate misuse of the diffusive sampler.