首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Flow—injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anionexchange Resin
引用本文:张四纯 ,周国俊 ,鞠熀先.Flow—injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anionexchange Resin[J].中国化学,2002,20(10):1049-1054.
作者姓名:张四纯  周国俊  鞠熀先
作者单位:ZHANG,Si-Chun ZHOU,Guo-Jun JU,Huang-XianDepartment of Chemistry,Institute of Analytical Science,State Key Laboratory of Coordination Chemistry,Nanjing University,Nanjing 210093,China
基金项目:ProjectsupportedbytheNationalNaturalScienceFoundationofChina (Nos .2 9975 0 13and 9835 110 )andtheDoctoralFoundationofEducationMinistryofChina (No.2 0 0 0 0 2 840 3)
摘    要:IntroductionGallicacidexistsintheleavesandfruitsofmanytypesofplantsandiswidelyusedinmedicineforanti oxi dationandantibacterialactivity ,antiflammatoryactionandanti canceractivity .1 5Inspiteofthehealthimportanceofgallicacid ,itsmetabolismandkineticsinthehu…

关 键 词:化学发光传感器  五倍子酸  氨基苯二酰一肼  高碘酸盐  阴离子化合物树脂  分析

Flow-injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anion-exchange Resin
ZHANG,Si-Chun ZHOU,Guo-Jun JU,Huang-Xian.Flow-injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anion-exchange Resin[J].Chinese Journal of Chemistry,2002,20(10):1049-1054.
Authors:ZHANG  Si-Chun ZHOU  Guo-Jun JU  Huang-Xian
Institution:ZHANG,Si-Chun ZHOU,Guo-Jun JU,Huang-XianDepartment of Chemistry,Institute of Analytical Science,State Key Laboratory of Coordination Chemistry,Nanjing University,Nanjing 210093,China
Abstract:A novel chemieluminescence (CL) sensor for the determination of gallic acid combined with flow injection analysis was developed by electrostatically immobilizing luminol and periodate on anion‐exchange resins respectively. Gallic acid was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The possible reaction mechanism of the CL system was suggested and discussed. The response of the sensor to gallic acid concentration was linear over the range of 8.0 × 10?9‐1.0 × 10?6 mol/L with a detection limit of 6.5 × 10?9 mol/L (3°). The relative standard deviation (RSD) for 7 repetitive determinations of gallic add (1.0 × 10?7 mol/L) was 1.8%. The sensor could be used for over 400 times determination with a good reproducibility.
Keywords:chemiluminescence sensor  gallic acid  luminol  periodate  flow-injection analysis
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号