首页 | 本学科首页   官方微博 | 高级检索  
     


Flow-Injection Fluorometric Determination of Novalgin in Pharmaceutical Preparations
Authors:Perezruiz T.   Martinezlozano C.   Tomas V.  Carpena J.
Abstract:
A flow-injection configuration for the fluorometric determination of Novalgin (dipyrone) is proposed. The procedure is based on the oxidation of Novalgin by cerium(IV). The fluorescence native of cerium(III) formed in the oxidation of Novalgin is monitored. Lineal calibration graphs were obtained between 0.5 and 4 μg/ml, with a sampling rate of 40 samples/h and relative standard deviations between 0.93 and 2.8%. The applicability of the method to the determination of Novalgin in pharmaceutical preparations was demonstrated by investigating the effect of potential interferences and by analysis of commercial preparations.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号