Abstract: | Characterization of fuels by LC-GC is possible by use of automatic successive transfer (multiple transfer) of HPLC fractions to a GC via an on-column interface. This paper describes the instrumentation and the methodology for the HPLC separation of the hydrocarbons (aliphatic and aromatic) into separate groups and the on-line transfer of these groups to a capillary GC column. Two HPLC methods were used with the same valve configuration: single column (silica) with column back-flush to detector; and double column (silica and amino-bonded silica) with multiple fraction transfer and back-flush. The first method was used for the analysis of total saturated compounds and total aromatic compounds; the second was used for the separation of the one-, two-, three-, and four-ring aromatic compounds present in diesel fuels. Examples are shown of the characterization of diesel fuels, and the repeatability of the data. |